Is Your Old DB Box Putting Your Home at Risk?
Many homeowners in Jalan Kebun don’t realize that one of the leading causes of house fires in Malaysia is outdated or overloaded electrical distribution boards (DB boxes). If you’re living in a home that was built in the 1980s, 1990s or even earlier there’s a good chance your DB box hasn’t been upgraded in decades.
Often hidden in a corner or behind a cabinet, these aging systems may seem harmless but in reality, they could be a silent fire hazard.
What Exactly Is a DB Box?
A DB box, or distribution board, is the main control center for your home’s electricity. It directs power to all circuits and plays a key role in protecting your home from electrical overloads and shocks.
Modern DB boxes include:
- Main Switch
- MCBs (Miniature Circuit Breakers)
- RCCBs (Residual Current Circuit Breakers)
- SPD (Surge Protection Device)
These components work together to ensure your electrical system runs safely and efficiently. If your current DB panel is outdated or using plastic casings, it’s time for a serious upgrade especially if you’re located in Jalan Kebun, where many properties are over 20 years old.

Why Upgrading Your DB Box in Jalan Kebun Is Crucial
In our site visits across Jalan Kebun and surrounding areas, we’ve seen many homes still running on original wiring systems and outdated protection devices like old ELCBs and basic MCBs. These older setups often fail to trip during short circuits or overloads, leaving your home exposed to potential fire hazards.
Modern lifestyles demand more powerthink:
- Air conditioners in every room
- Laptops, gaming PCs, iPads, and printers
- High-wattage kitchen appliances like ovens, air fryers, and hoods
- Cuckoo water filters, autogates, and large washing machines
Most old DB boxes simply aren’t built to handle this load.
Key Components in a Modern DB Box
When you choose us for a DB box upgrade in Jalan Kebun, here’s what we install:
MCBs (Miniature Circuit Breakers)
- C6 MCBs for lighting/fan circuits
- C16 MCBs for power sockets
Function: Automatically disconnects power in the event of a short circuit or overload.
RCCBs (Residual Current Circuit Breakers)
- 40A 30mA RCCB for sockets
- 40A 100mA RCCB for lighting and fan circuits
Function: Detects current leakage and protects you from electric shock.
Main Isolator Switch
- 63A Double Pole Switch
Function: Lets you safely shut off power to the entire board during servicing or emergencies.
Copper Busbars
Efficiently distributes current to each MCB. We only use high-conductivity copper for safety and durability.
- SPD (Surge Protection Device)
Especially important in areas like Jalan Kebun, where lightning strikes are common.
Function: Shields your appliances from dangerous voltage spikes.
- Metal Clad Enclosure
We use only metal-cased DB boxes (known as metal clad) for their superior fire resistance compared to old plastic units.
Brands We Trust
We only use reliable, SIRIM-compliant brands such as:
- EPS
- Maxguard
- ABB
- Hager
We don’t cut corners. That means no low-quality, mix-and-match “rojak” DB setups. Every component we install is chosen for safety, performance, and long-term reliability (up to 20 years).
Old DB Boxes Aren’t Built for Modern Power Loads
Gone are the days when one or two sockets per room were enough. Now, every family member needs their own devices and climate control. Here’s what typically happens in homes with old DB boxes:
- Circuit breakers keep tripping when turning on the air conditioner or washing machine
- One socket powers multiple devices using a 5-gang adapter—causing dangerous overloads
- Wires inside the DB are tangled, messy, and not labeled, making future upgrades risky
- There’s no surge protection, increasing risk during thunderstorms
And during Malaysia’s post-MCO work-from-home trend, we’ve seen even more homes maxing out their electrical systems.
12 Signs You Need a DB Box Upgrade in Jalan Kebun
- Home is 20+ years old
- DB trips during rain or lightning
- Power cuts out when turning on large appliances
- Washing machine causes tripping
- Kitchen hood, oven or hob causes sudden shutdown
- Vacuuming trips the breaker
- Too many devices plugged into extensions
- Messy, tangled, or unlabeled wiring in the panel
- No RCCB/ELCB installed
- Multiple wires sharing one MCB
- Burning smell from the panel
- No space to add more breakers or power points
If you notice any of these, it’s time to call a electrician for inspection.
Why Choose Us for DB Box Upgrades in Jalan Kebun?
We’re based near Jalan Kebun and know the unique electrical challenges in this area. Whether you live in a single-storey terrace or a 2½-storey corner lot, we offer tailored, code-compliant solutions to protect your home.
- Proper circuit separation & labeling
- Neat, safe wiring that meets Suruhanjaya Tenaga guidelines
- Fast, local service with no compromise on safety
- High-quality materials and workmanship
- More Than Just DB Box Upgrades
We also offer a full range of residential and commercial electrical services, including:
- Earthing and grounding system installation
- New house wiring and rewiring
- Autogate and outdoor lighting wiring
- Lightning Strike Trap (LST) systems
- Megger insulation testing
- Troubleshooting for tripping issues
- Surge protection for sensitive appliances
Book Your Electrical DB Box Upgrade in Jalan Kebun Today
Don’t wait until a tripping issue or electrical fire forces your hand. If your DB box in Jalan Kebun is outdated, overloaded, or simply can’t keep up—now is the time to act.
Call Alex at 012-870 2699 for a quick site inspection or to request a quote.





